Pool/Spa

Blowers ( ) See Remarks ( ) N/A

( ) Operational ( ) Adverse Conditions [F] ( ) Inoperative [A] ( ) Noisy [M] ( ) Not grounded [S]

Electrical ( ) See Remarks ( ) N/A

( ) Operational ( ) Adverse Conditions [F] ( ) Improper wiring [A] ( ) Deteriorated/separated conduit [A]

( ) Missing/damaged cover plates [A] ( ) Loose cover plates [A] ( ) Switch inoperative [A] ( )Pool/spa light inoperative [A]

( ) Underwater light operation not determined [C] ( ) No GFCI protection found [S] ( ) GFCI protection inoperative [A]

( ) Timer inoperative [A] ( ) Timer latch damaged [A] ( ) Timer missing interior plastic safety cover [S]

( ) Suggest installing timer(s) [M]

Filter ( ) See Remarks ( ) N/A

( ) CARTRIDGE ( ) DIATOMACEOUS EARTH ( ) SAND ( ) UNDETERMINED

( ) Appears Operational (not disassembled or tested for effectiveness) ( ) Adverse Conditions [F] ( ) Gauge inoperative [A]

( ) Gauge damaged [A] ( ) No gauge provided [F] ( ) Air bleed valve leaks [A] ( ) Air bleed valve inoperative [A]

( ) Air bleed valve missing [M] ( ) Dome leaks [A] ( ) Corrosion/deterioration at shell [M] ( ) Leaking noted at band [A]

General ( ) See Remarks ( ) N/A Check your local ordinance regarding pool/spa fencing requirements.

( ) Appears Functional ( ) Adverse Conditions [F] ( ) Child safe provisions inoperative/incomplete [S]

( ) No child safe provisions provided [S] ( ) Gate latch mounted below 54" [S] ( ) Gate swings in toward pool [S]

( ) Gate self closure missing/inoperative [S] ( ) Gate not self closing/latching [S] ( ) Gaps in fencing larger than 4" [S]

( ) Fencing too low [S] ( ) Fencing climbable [S] ( ) Adjacent metal fencing/structure components are not grounded [S]

( ) Slide damaged [A] ( ) Slide loose [A] ( ) Slide water lines damaged/missing [A] ( ) Diving board cracked/damaged [A] ( ) Diving board loose [A] ( ) Fill valve missing/inoperative [F] ( ) Fill valve needs to be anti-siphon protected [A]

( ) Restricted equipment access [F] ( ) Equipment stand is damaged [M] ( ) In pool cleaning system needs service [A]

( ) In pool cleaning system inoperative [A] ( ) In pool cleaning system not evaluated [F] ( ) No cleaning system provide [C]

( ) Filter appears to be undersized [F] ( ) Water purification system installed-Not a part of this inspection [F]

( ) Pool/Spa over-filled/under-filled [F] ( ) Skimmer/leveler cover damaged/missing [A]

( ) Complete system evaluation required [F] ( ) Equipment older-Budget to Replace [M]

( ) Single drain installed at shallow pool/spa-Safety cover suggested [S]

Heater ( ) See Remarks ( ) N/A Heater size and or adequacy determinations are not provided as a part of this inspection.

( ) ELECTRIC ( ) GAS ( ) SOLAR (NOT TESTED)

( ) Operational ( ) Adverse Conditions [F] ( ) Inoperative [A] ( ) Inactive-Not tested [F] ( ) Appears abandoned [F]

( ) Gas off-Not tested [F] ( ) No gas shut off [S] ( ) Vents filled with debris [A] ( ) Vent too close to combustibles [S]

( ) Burner area needs cleaning/service [A] ( ) Inlet/outlet piping corroded [M] ( ) Plastic inlet/outlet piping [F]

( ) Piping leaks [A] ( ) Unit leaks [A] ( ) Unit cycles [F] ( ) Shell corroded/damaged [M] ( ) Shell not grounded [S]

( ) TPR safety valve not found [F] ( ) TPR safety valve piping missing/short/runs uphill/unsafe termination [S]

( ) Water not warmed-Full heater operation not confirmed [F]

Pool/Spa Shell ( ) See Remarks ( ) N/A Leak testing and testing for unsafe drain conditions are not a part of this inspection.

( ) FIBERGLASS ( ) PAINTED ( ) PEBBLE SURFACE ( ) PLASTER ( ) TILE ( ) VINYL ( ) _______________

( )Appears Functional ( ) Adverse Conditions [F] ( ) Cracking [F] ( ) Rust/rebar showing [A] ( ) Mineral buildup [A]

( ) Bottom not visible-Inspection limited [F] ( ) Moderate/major algae noted [A] ( ) Plaster deteriorated/spalling/rough [M]

( ) Surface stained [M] ( ) Water level tiles missing/damaged [A] ( ) Deck surface deteriorated/spalling [M]

( ) Deck cracks noted [M] ( ) Damaged deck joints noted [A] ( ) Deck area raised/settled/trip hazard [S]

( ) Coping damaged [M] ( ) Drain cover missing/damaged [A] ( ) Perimeter caulking needed at gaps [A]

Pumps/Valves/Piping ( ) See Remarks ( ) N/A Pressure and underground piping leak testing is not a part of this inspection.

Valves are not operated during the inspection.

( ) Operational (Valves not operated) ( ) Adverse Conditions [F] ( ) Pump inoperative [A] ( ) Pump body not grounded [S]

( ) Pump leaks [A] ( ) Pump noisy [M] ( ) Pump appears abandoned-Not tested [C] ( ) Piping leaks detected [A]

( ) Sun burned/exposed piping-Suggest reflective paint [A] ( ) Valve leaks detected [A] ( ) Valve handles missing/damaged [A] ( ) Valve(s) inoperative [A] ( ) Valve(s) cracked/damaged [A] ( ) Low pressure noted [F] ( ) High pressure noted [F]

( ) Air entering system [F] ( ) Aerator head damaged/missing [A]

Remarks: ___________________________________________________________________________________________________

____________________________________________________________________________________________________________

____________________________________________________________________________________________________________

____________________________________________________________________________________________________________

____________________________________________________________________________________________________________

____________________________________________________________________________________________________________

____________________________________________________________________________________________________________

____________________________________________________________________________________________________________

Key to Symbols: [A] Attention Required [C] Consult Seller [E] Engineering Consult [P] Pest control consult [F] Further review suggested [M] Monitor or repair [S] Safety issue