Can Do | |
| Home Inspections Inc. | ||
| 3032 S. Paseo Loma Circle | ||
| Mesa, AZ 85202-7951 | ||
| Voice or Fax 480-831-6237 | ||
| Arizona Home Inspections By |
| Arizona State Certified Home Inspector #39760 |
| Arizona Board of Technical Registration Firm #11968 |
|
Kitchen |
|
Built In Appliances ( ) See Remarks ( ) N/A Proper operating temperature of refrigerator is not verified as a part of this inspection. |
|
( ) Microwave operational ( ) Microwave inoperative [F] ( ) Microwave damaged [A] ( ) Microwave not tested [F] ( ) Refrigerator operational ( ) Refrigerator inoperative [F] ( ) Refrigerator Damaged [A] ( ) Refrigerator not tested [F] ( ) Compactor operational ( ) Compactor inoperative [F] ( ) Compactor damaged [A] ( ) Compactor Not tested [F] ( ) Toaster operational ( ) Toaster inoperative [F] ( ) Toaster damaged [A] ( ) Toaster not tested [F] ( ) Instant hot water operational ( ) Instant hot water unit inoperative [F] ( ) Instant hot water unit damaged/corroded [A] ( ) Blender operational ( ) Blender inoperative [F] ( ) Blender damaged [A] ( ) Blender not tested [F] Installed and not a part of this inspection: ( ) Bread Warmer ( ) Coffee maker ( ) Ice maker ( ) Water purifier ( ) _____ [F] |
|
Cabinets/Counters ( ) See Remarks ( ) N/A |
|
( ) Appears Functional ( ) Adverse Conditions [F] ( ) Damaged/worn/chipped [M] ( ) Loose tile [A] ( ) Cracked tile [M] ( ) Missing/damaged grout/caulking [A] ( ) Counter/cabinets not secured [A] ( ) Island not secure-May tip over [S] ( ) Missing/loose handle(s) [A] ( ) Door(s) won't latch [A] ( ) Kick plate missing [A] ( ) Moisture damage below sink [A] ( ) Damaged/missing ______________________________________________________________________________________ [A] |
|
Dishwasher ( ) See Remarks ( ) N/A Cleaning effectiveness and timer not evaluated as a part of this inspection. |
|
( ) Appears Functional ( ) Adverse Conditions [F] ( ) Inoperative [A] ( ) Unit not tested-Appears to be abandoned [C] ( ) Leaking below unit [A] ( ) Would not drain [A] ( ) Not secured to counter [A] ( ) Unit older-Budget to replace [M] ( ) Door seal damaged [A] ( ) Door hinges sprung/open beyond 90 degrees [A] ( ) Door does not shut properly [A] ( ) No air gap device or high loop present [A] ( ) Air gap device leaks [A] ( ) Racks rusted minor/moderate/major [M] ( ) Spray arm was immovable/difficult to rotate [A] ( ) Makes excessive noise [M] ( ) Portable unit(s) not tested [F] ( ) Discharge line leaks [A] ( ) Discharge line not visible [F] ( ) Discharge line deteriorated at disposal connection [A] ( ) Does not drain completely [A] ( ) Controls damaged/missing [A] ( ) Soap dish damaged/inoperative [A] ( ) Rinse agent cap missing [A] ( ) Electrical connection not visible [F] ( ) Kick plate missing [A] ( ) Unit not level [A] ( ) Heating /drying element did not operate [A] ( ) Leaking observed at door [A] |
|
Garbage Disposal ( ) See Remarks ( ) N/A |
|
( ) Operational ( ) Adverse Conditions [F] ( ) Inoperative [A] ( ) Splash guard worn [M] ( ) Splash guard missing [A] ( ) Interior worn/corroded-Budget to replace [M] ( ) Unit noisy/vibrates [A] ( ) Disposal is hard wired-No disconnect [S] ( ) Missing cable grip [A] ( ) Corroded/leaking below sink [A] |
|
Range/Oven ( ) See Remarks ( ) N/A Temperature calibration/clock timer and self cleaning features are not a part of this inspection. |
|
( ) ELECTRIC ( ) GAS ( ) Operational ( ) Adverse Conditions [F] ( ) Inoperative [A] ( ) Unit not tested-appears to be abandoned/gas shut off [C] ( ) Unit trips breaker/dims lights under full power-further review required [A] ( ) Missing/damaged control knobs [A] ( ) Range elements not level [F] ( ) Range element did not operate at ____________________________________________ [A] ( ) Range hood light inoperative [A] ( ) Range hood is not secured [A] ( ) Range/oven controls damaged [A] ( ) Unit older-Budget to replace [M] ( ) Oven element did not operate at __________________________________________ [A] ( ) Oven door handle loose/missing/damaged [A] ( ) Oven is not secured to cabinet [A] ( ) Oven light inoperative [A] ( ) Exhaust fan noisy [A] ( ) Exhaust fan inoperative [A] ( ) Exhaust fan missing [A] ( ) Exhaust fan/hood needed [S] ( ) Vent filter missing [A] ( ) Vent filter dirty [A] ( ) Vent piping disconnected [A] ( ) Vent terminates in attic [A] ( ) Door gasket/glass damaged [M] ( ) Door would not close properly [A] ( ) Door springs appear to be damaged [A] ( ) Suggest anti-tip provisions at the range/oven [S] |
|
Sink/Piping ( ) See Remarks ( ) N/A Operational means flow and drainage was found to be functional. |
|
( ) Operational ( ) Adverse Conditions [F] ( ) Damaged/worn/chipped [M] ( ) Corroded at underside [M] ( ) Leaking below sink [A] ( ) Evidence of past leakage [M] ( ) Faucet loose [A] ( ) Faucet leaks at stem seal [A] ( ) Faucet drips continuously [A] ( ) Low volume at hot/cold [F] ( ) Hot and cold reversed [S] ( ) Spray wand leaks [A] ( ) Spray wand inoperative [A] ( ) Fixtures corroded [M] ( ) Slow draining [F] ( ) Supply/drain piping is improper [F] ( ) Restricted view below sink(s) [F] ( ) Supply valve handle(s) missing [A] ( ) Supply piping/valve leaks noted [A] ( ) Supply piping corrosion/evidence of past leakage noted [M] ( ) Waste piping corrosion/evidence of past leakage noted [M] ( ) Waste piping leaks noted [A] ( ) Waste piping slope is inadequate [A] ( ) Drain fitting cracked/damaged [M] ( ) Recommend caulking perimeter of sink [A] ( ) Back splash needs caulking [A] ( ) Aerator(s) clogged/missing [A] |
|
Remarks: ___________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ |
|
Key to Symbols: [A] Attention Required [C] Consult Seller [E] Engineering Consult [P] Pest control consult [F] Further review suggested [M] Monitor or repair [S] Safety issue |