Can Do | |
| Home Inspections Inc. | ||
| 3032 S. Paseo Loma Circle | ||
| Mesa, AZ 85202-7951 | ||
| Voice or Fax 480-831-6237 | ||
| Arizona Home Inspections By |
| Arizona State Certified Home Inspector #39760 |
| Arizona Board of Technical Registration Firm #11968 |
|
Interior |
|
Exterior Doors ( ) See Remarks ( ) N/A We suggest re-keying all doors for safety. Door screens not a part of this inspection. |
|
( ) Operational ( ) Adverse Conditions [F] ( ) Damage at ____________________________________________________ [A] ( ) Weather strip damaged/missing at _________________________________________________________________________ [A] ( ) Rubs/sticks/difficult to operate at _________________________________________________________________________ [A] ( ) Door would not lock/latch at _____________________________________________________________________________ [A] ( ) Exterior doors hollow core [S] ( ) Door(s) rub on floor [A] ( ) Dual cylinder dead bolt may prevent emergency exit [S] ( ) Threshold damaged/loose [A] ( ) Could not confirm safety glass [S] ( ) Sliding glass panel mounted to outside of frame [S] ( ) Doorbell damaged/inoperative [A] ( ) No doorbell [M] ( ) Loose doorbell [A] |
|
Interior Doors ( ) See Remarks ( ) N/A |
|
( ) Operational ( ) Adverse Conditions [F] ( ) Damaged at ___________________________________________________ [A] ( ) Door would not lock/latch at _____________________________________________________________________________ [A] ( ) Rubs/sticks/difficult to operate at _________________________________________________________________________ [A] ( ) Closet door bottom glides missing/damaged at _______________________________________________________________ [A] ( ) Doors rub on flooring [A] ( ) Missing components at _______________________________________________________ [A] |
|
Windows ( ) See Remarks ( ) N/A Confirm that all bedrooms have an easily useable fire escape. All windows may not have been accessible/tested. Window screens are not a part of this inspection. |
|
( ) MULTI PANE ( ) SINGLE PANE ( ) STORM WINDOW(S) ( ) METAL ( ) WOOD ( ) VINYL ( ) AWNING ( )CASEMENT ( ) DOUBLE HUNG ( ) FIXED ( ) LOUVERED ( ) SINGLE HUNG ( ) SLIDING ( ) Operational ( ) Adverse Conditions [F] ( ) Adjacent stains/Damage noted [F] ( ) Some/all painted shut [A] ( ) Rubs/sticks/difficult to operate at ________________________________________________________________________ [A] ( ) Missing/loose/damaged/inoperative hardware at ____________________________________________________________ [A] ( ) Broken glass/dual pane seal at ___________________________________________________________________________ [A] ( ) Springs damaged [A] ( ) Safety glazing not verified at impact risk areas [S] ( ) Window tracks need cleaning [A] ( ) Security bars installed at bedroom(s) without quick release [S] ( ) Bedroom egress windows too high/too small [S] ( ) Screens installed/windows dirty-Dual pane seal condition not verified [F] |
|
Floors ( ) See Remarks ( ) N/A Possessions are not moved during this inspection-hidden damage may exist. |
|
( ) CARPET ( ) CONCRETE ( ) EXPOSED CONCRETE ( ) FRAMED ( ) STONE ( ) TILE ( ) VINYL ( ) WOOD/WOOD REPLICA ( ) FLOOR STRUCTURE NOT VISIBLE-Inspection limited [F] ( ) Appears Functional ( ) Adverse Conditions [F] ( ) Damaged at _____________________________________________ [A] ( ) Cracked/chipped/broken tile(s) noted [M] ( ) Damaged/missing grout [M] ( ) Damaged/deteriorated vinyl [M] ( ) Damaged/deteriorated wood [M] ( ) Carpet needs re-stretching [A] ( ) Squeaky floors noted [M] ( ) Uneven areas [F] |
|
Walls/Ceilings ( ) See Remarks ( ) N/A Sources of stains are not confirmed. Evidence of moisture may indicate a mold/health risk. |
|
( ) ACOUSTIC ( ) DRYWALL ( ) EXPOSED WOOD ( ) MIRRORS ( ) PANELING ( ) PLASTER ( ) WALLPAPER ( ) Appears Functional (Normal cracks) ( ) Adverse Conditions [F] ( ) Broken mirrors [S] ( ) Loose paneling [F] ( ) Damage at ____________________________________________________________________________________________ [A] ( ) Moisture staining /damage at _____________________________________________________________________________ [F] |
|
Fireplace/Stairs/Railings/General ( ) See Remarks ( ) N/A Occupants possessions prevent a full inspection - Check carefully at final walk through.. Smoke detectors are not tested as a part of this inspection. |
|
( ) Fireplace Appears Functional ( ) Adverse Conditions [F] ( ) Missing fireplace screen [S] ( ) Hearth too small [S] ( ) Firebox mortar/bricks need repair [A] ( ) Firebox refractory panels cracked [M] ( ) Soot at face [F] ( ) Improper clearance to combustibles [S] ( ) Gap at lintel area needs to be sealed [A] ( ) Damper was inoperative [A] ( ) Gas supplied with closeable damper [S] ( ) Gas supply not evaluated [F] ( ) Wall/flooring protection is improper [F] ( ) Recommend chimney cleaning at __________________________________________________________________________ [A] ( ) No smoke detector(s) found [S] ( ) Additional smoke detectors needed [S] ( ) Additional smoke detectors recommended [S] ( ) Stairway head clearance is inadequate [S] ( ) Stairway is too steep/narrow [S] ( ) Stairway rise/run is inconsistent [S] ( ) Stairs handrail loose Missing [S] ( ) Stairs handrail improper height/openings too large [S] ( ) Balcony needs repair [A] ( ) Ceiling fan(s) are mounted below 7' blade height [S] ( ) Ceiling fan(s) wobble/support needs review [M] ( ) Ceiling fan(s) damaged/inoperative [A] ( ) Carbon Monoxide detectors recommended [S] ( ) Wet bar inoperative [F] ( ) Wet bar supply line leaks [A] ( ) Wet bar drain line leaks [A] ( ) Wet bar faucet leaks [A] ( ) Evidence of past leaks [F] ( ) Ice maker not inspected [F] |
|
Remarks: ___________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ |
|
Key to Symbols: [A] Attention Required [C] Consult Seller [E] Engineering Consult [P] Pest control consult [F] Further review suggested [M] Monitor or repair [S] Safety issue |
Page 9
Who can do home inspections?
Can Do Home Inspections, AZ Home Inspectors performing AZ Home Inspections.
Copyright 2006 Can Do Home Inspections Inc.