Structure |
|
Basement/Crawl Space ( ) See Remarks ( ) N/A Access must be clear and larger than 30" in all directions to allow inspector to enter. |
|
( ) ENTERED FULL ACCESS ( ) ENTERED PARTIAL ACCESS [F] ( ) NOT ENTERED-VIEWED FROM OPENING [F] ( ) BLOCK ( ) BRICK ( ) CONCRETE ( ) PIERS/POSTS ( ) STONE ( ) _______________________________________ ( ) FLOOR FRAMING: MAIN BEAMS ____ X ____ JOISTS ____ X ____ ( ) NOT DETERMINED ( ) Appears Functional (at visible areas) ( ) Adverse Conditions [F] ( ) Severe cracks [E] ( ) Moisture present [A] ( ) Evidence of past moisture [F] ( ) Earth/wood contact [P] ( ) Evidence of insects [P] ( ) Debris [A] ( ) Uneven areas [E] ( ) No insulation [F] ( ) Vapor barrier needed [A] ( ) Area ventilation inadequate [A] ( ) Sump pump did not operate [A] ( ) Pump not tested [F] ( ) Sump pump needed [A] ( ) Head clearance low at stairs [S] ( ) Handrail loose at stairs [S] ( ) Handrail missing [S] ( ) Stairway lighting inadequate [S] ( ) Mud tubes noted [P] ( ) Straps not visible [M] ( ) Screens/doors needed at opening(s) [A] ( ) Seismic upgrades needed [E] ( ) Mud tubes noted [P] ( ) Broken/sagging/cut framing [A] ( ) Need berm to protect access from site run off [A] |
|
Chimney ( ) See Remarks ( ) N/A Draft/Function and Interior Integrity is not verified during this inspection. |
|
( ) BLOCK ( ) BRICK ( ) METAL ( ) METAL/STUCCO ( ) __________________________________________________ ( ) Appears Functional (normal cracks) ( ) Adverse Conditions [F] ( ) Moderate cracks [M] ( ) Severe cracks [E] ( ) Loose bricks [A] ( ) Unlined Flue [S] ( ) No spark screen/rain cap installed [S] ( ) Spark screen loose/improper [A] ( ) Metal cap is not fit/secure/sealed [A] ( ) Prior patching evident [C] ( ) Stucco needs repair at ______________________ [A] ( ) Flue storm collar/band flashing is missing at top of chimney [A] ( ) Cracking at mortar domed top needs repair [A] ( ) No saddle provided at 36" or larger chimney [F] ( ) Chimney(s) requires evaluation [F] ( ) Chimney(s) not fully visible [F] ( ) Paint /finish deterioration [A] ( ) Trim vegetation away from chimney top [S] |
|
Structure Slab/Foundation ( ) See Remarks ( ) N/A Floor coverings are not removed during this inspection. |
|
( ) BLOCK ( ) BRICK ( ) CONCRETE ( ) STONE ( ) WOOD ( ) ________________________________________ ( ) Visible perimeter Appears Functional (normal cracks) ( ) Adverse Conditions [F] ( ) Exterior not fully visible [F] ( ) Interior not visible due to floor coverings-inspection limited ( ) Suggest further evaluation/removal of floor covering [E] ( ) Uneven areas [F] ( ) Moderate cracks [M] ( ) Severe cracks [E] ( ) Spalling concrete stem wall [A] ( ) Stem wall/paint/surface deterioration [A] ( ) Horizontal cracking at stem wall [A] ( ) Differential movement noted [E] ( ) Evidence of termite treatment [C] ( ) Mud tubes noted at _____________________________________________________ [P] ( ) Interior/exterior doors severely racked out of square [E] ( ) Stucco installed to grade-perimeter not visible- inspection limited [F] |
|
Structure Walls/Cladding/Columns ( ) See Remarks ( ) N/A Structural integrity certification is not a part of this inspection. |
|
( ) ADOBE ( ) BLOCK ( ) BRICK ( ) FIBROUS SIDING ( ) FRAMED ( ) METAL SIDING ( ) STUCCO ( ) VINYL SIDING ( ) WOOD SIDING ( ) UNDETERNINED ( ) _______________________________________________ ( ) Appears Functional (normal cracks) ( ) Adverse Conditions [F] ( ) Moderate cracks [M] ( )Severe cracks [E] ( ) Wood deterioration [P] ( ) Wood siding cracked [A] ( ) Caulk/seal all gaps and openings [A] ( ) Mortar deterioration [A] ( ) Paint/finish deterioration [A] ( ) Siding seams separated [A] ( ) Popped nails/loose siding [A] ( ) Brick spalling [F] ( ) Parapet repairs needed [A] ( ) Scupper penetrations need repair [A] ( ) Not fully visible [F] ( ) Wall patching/repairs noted [C] ( ) Holes/damage noted at __________________________________________________ [A] ( ) Column defects/damage noted at ___________________________________________________ [A] ( ) Stucco damage noted at ____________________________________________ [A] ( ) Attached elevated planter noted-possible moisture migration to interior [M] ( ) No address numbering found [S] |
|
Trim/Flashing/Eaves/Soffits/Fascia ( ) See Remarks ( ) N/A |
|
( ) METAL ( ) VINYL ( ) WOOD ( ) UNDETERMINED ( ) __________________________________________________ ( ) Appears Functional ( ) Adverse Conditions [F] ( ) Window glazing deteriorated [A] ( ) Porch ceiling cracked/damaged [M] ( ) Deterioration/water stains at _____________________________________________________________________________ [F] ( ) Loose/damaged/missing trim at __________________________________________________________________________ [A] ( ) Paint/finish deteriorated [A] ( ) Caulking needed at window/door perimeters [A] ( ) Flashing not fully visible [M] ( ) Caulking/repairs needed at _______________________________ [A] ( ) Wall flashing missing [A] |
|
Remarks: ___________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ ____________________________________________________________________________________________________________ |
|
Key to Symbols: [A] Attention Required [C] Consult Seller [E] Engineering Consult [P] Pest control consult [F] Further review suggested [M] Monitor or repair [S] Safety issue |